Flow measurement specialists at Nivus have developed a wireless, continuous river monitoring solution designed to meet the requirements of water managers and regulators such as the Environment Agency (EA) in England. Using satellite technology, the new Wireless Transit Time (WTT) method eliminates the need for invasive capital works across or beneath rivers.
Background
River flow measurements underpin several of the EA’s core functions, including flood warning, modelling, forecasting and planning, as well as the management of water infrastructure and abstraction licences. Flow monitoring also informs the EA’s work to track long-term changes in catchments and assess the effects of climate change.
The EA operates around 7,000 hydrometric monitoring stations across England. These collect high-resolution data, mainly at 15-minute intervals, on river flow, river level, groundwater and rainfall, alongside daily measurements.
“The measurement of river flow in England presents a particular set of challenges,” explained Sam Everitt, national hydrometry advisor at the EA. “We monitor everything from slowly responding lowland rivers to catchments that can experience rapid changes in flow during storm events. This means that flow monitoring technology has to be sufficiently robust and versatile to perform reliably across a wide range of river conditions.”
The EA uses a variety of flow measurement techniques, with the Transit Time method having been employed for decades to monitor relatively clean rivers. Traditionally, one of the main drawbacks of the method has been the need to install cabling across or beneath the river.
Transit Time flow monitoring
The standard Transit Time method, covered by ISO 6416, relies on highly accurate measurements of acoustic signals transmitted upstream and downstream. Sensors are installed on both banks of a river, exploiting the fact that sound waves travel faster in the direction of the flow than against it. One sensor transmits a signal downstream, which is received by the transmitter/receiver on the opposite bank. The process is then reversed to measure the upstream signal.
Flow velocities are determined by calculating the difference between the upstream and downstream signal transmission times. This provides a full velocity profile of the river, rather than spot velocity measurements used by some alternative methods.
Compared with traditional methods such as mechanical meters, Acoustic Doppler Current Profilers (ADCPs) and tracer injections, the Transit Time method offers several advantages. It provides continuous measurements, has a lower environmental impact, does not rely on tracers, particles or bubbles, is less sensitive to localised turbulence and misalignment, delivers highly reproducible total discharge measurements and requires minimal maintenance.
Explaining the advantages of Transit Time monitors, Nivus’s Alistair MacKinnon said: “We can apply this method to a wide range of channel sizes, and for rivers up to 200m wide. Deep water can also be accommodated with multiple sensors and signal paths. In addition, some of these signal paths can be redundant to account for fault conditions or obstructions.”
However, the Transit Time method can be unsuitable for waters containing high levels of suspended solids or weed, as well as water with entrained air bubbles.
Because the method involves extremely fast measurements, in the nanosecond range, the internal timing of the transmitters and receivers must be synchronised with a high degree of accuracy. Traditionally, sensors on both banks have therefore been connected by cross-river cabling, significantly increasing installation costs.
This typically involves civil engineering works and the installation of cross-river ducting on the riverbed, which can require the river to be dammed or diverted. Installing ducting can negatively affect river ecology and, once in place, may pose a hazard to human activities. The ducting and cabling can also be vulnerable during severe weather events.
Wireless Transit Time (WTT)
The Nivus WTT solution retains the accuracy of the Transit Time method without the associated costs and disadvantages of a cabled system. The WTT sensors communicate across the river using Wi-Fi, while GPS satellites with atomic clocks maintain the required timing accuracy.
Sustainability was a key consideration in the development of the Nivus WTT solution. The system can operate entirely on solar power, providing an off-grid solution that can be deployed in a range of locations. Ground screws are used to anchor the bankside equipment, eliminating the need for concrete and simplifying decommissioning.
Case study: River Ouse, UK
A Nivus WTT system has recently been installed on the River Ouse at Barcombe Mills, close to Barcombe Reservoir in East Sussex. The new system replaced an older Transit Time monitor that had failed.
The EA and its predecessor, the National Rivers Authority, have monitored river flow at the site for more than 30 years. The previous system used a cross-river duct laid on the riverbed and weighed down with clay chimney pots.
Theo Parfitt, from the EA’s regional hydrometry & telemetry team, explained the options: “It would be possible to bore a tunnel under the river, but this requires tunnelling to begin at some distance from the river to create the correct angle of bore. However, aside from the high cost, the proximity of the reservoir rendered this option redundant. Similarly, replacement of the cross-river ducting was disregarded because of cost and environmental issues. It was fortuitous, therefore, that our working partnership with Nivus had developed a beneficial solution.”
The Ouse is approximately 20m wide at Barcombe Mills, and the cost of a Nivus WTT system was estimated at around 25% of that of a ducted system.
“The previous system included two sets of sensors in submerged racks on either bank, with eight signal paths,” Theo explained. “Fortunately, these sensors could be utilised by the new WTT system, which also helped to lower costs.”
The future of WTT flow monitoring
The EA already operates two WTT systems in North London and Yorkshire. Both Nivus installations are mains powered, making Barcombe Mills the first to be fully solar powered.
Looking ahead, Everitt said: “This is a good example of the ways in which the EA can leverage its size and expertise, working with specialist partners, to develop innovative solutions that save money and enhance environmental protection. Given these advantages, we are looking to switch our existing Transit Time monitors to wireless versions as they come up for renewal. The new technology appears to be working very well, and has prompted interest from our counterparts in North America and Scandinavia.”